Anemostat Cable Operated Damper
Operating mechanism provides for a positive damper setting in a position from fully opened to fully close rotating blades are tensioned with music wire to maintain setting and prevent rattling 24 x 24 is maximum one piece construction.
Anemostat cable operated damper. Damper with flexible cable for remote adjustment. No wall or ceiling penetrations are required. This damper uses a worm gear mechanism requiring minimal torque at the end of the cable and is ideal for longer cable lengths tighter cable bend radii and larger dampers. View more arrow united industries fire dampers fire smoke dampers smoke dampers.
Direct cable to damper connection. Flex duct bends may interfere with operation of damper and is not recommended. Factory welded to neck. Flex duct bends may interfere with operation of damper and is not recommended.
The ld louver damper can be added to any anemostat round neck diffuser or sra square to round adapter. Ob7s same construction features as the ob1 damper but with a flexible cable directly attached to the damper. 5 32 hex key required. The vd damper can be added to any anemostat round neck diffuser or sra square to round adapter.
The damper is adjusted via rotary cable actuation using a nut driver or flat head screwdriver. Vav damper belimo lmb24sr motor w 2 10vdc 3045. Vav damper auto changeover w relay. Cable is routed inside the ductwork and terminated at the diffuser face.
Stainless steel front operated opposed blade volume control damper model ob1. Airflow balancing and damper adjustment is performed at the face of the diffuser. Anemostat a mestek company architectural specialty air distribution products air discharge jet nozzles. Other latch configurations available including bail handles wing head and tool operated fasteners weep holes as required cable driven dampers available for remote operation beveled mitered welded outer frame.
After balancing is complete the cable is recessed behind the diffuser. View more vibro acoustics manufacturers of fine acoustical products. The actuator at the end of the adjustment cable is accessible from the diffuser grille internal or is routed to an appropriate area such as a wall mount external. Damper is adjusted via rotary cable actuation using a nut driver or flat head screwdriver.
Engineered custom acoustic solutions silencers attenuators for the entire industry acoustical barriers plenums acoustic plenums. Airflow balancing and damper adjustment are performed at the face of the diffuser. The blades are conveniently adjusted from the room side of the diffuser and are designed to hold their position indefinitely.