Annual Fire Door Inspection Form
Full compliance with the annual fire door assembly inspection and testing in accordance with 2010 nfpa 80 is required by january 1 2018.
Annual fire door inspection form. The 2012 edition of the life safety code nfpa 101 requires facilities to complete annual fire and smoke door inspection and testing. Nfpa 80 requires both sides of swinging fire doors to be inspected and tested according to the following 13 items. Does the active door leaf completely close when. Fill out securely sign print or email your annual inspection of swinging fire door assemblies healthandwelfare idaho instantly with signnow.
Cms annual inspection per nfpa 101. Is the door free from missing or broken parts. Available for pc ios and android. Annual fire door inspection form.
Start a free trial now to save yourself time and money. Fire door field labeling and certification as defined in nfpa 252 or ul 10b c. Annual inspection of fire and egress doors. Is the clearance from the door edge to the frame no more than 1 8 inch.
Is the door undercut no more than inch. Section 18 2 2 2 1 19 2 2 2 1 requires compliance with section 7 2 1 and section 7 2 1 15 2 requires compliance with nfpa 80 standard. Section 7 2 1 15 also addresses the annual inspection of fire doors performed in accordance with nfpa 80 and smoke doors performed in accordance with nfpa 105 for fire doors and smoke doors in all occupancy types. Manual fire alarm boxes ion detectors photo detectors duct detectors heat detectors waterflow switches supervisory switches other specify.
Fire door inspections annual fire door inspections were introduced with the adoption of the 2007 edition of nfpa 80. It is recommended that a facility identify all doors to be inspected on drawing layout of the facility to track inspections. 13 points points doors inspection. Life safety code lsc deficiencies associated with the annual inspection and testing of fire doors should be cited under k211 means of egress general.
Nfpa 101 requires annual fire and smoke door inspections section 18 19 2 2 2 1 sections 18 19 2 2 1 require compliance with. Are the doors hinges frame hardware and threshold secure aligned and in working order with no visible signs of damage. Inspection and testing form nfpa inspection and testing 1 of 4 alarm notification appliances and circuit information quantity êêêêcircuit style bells horns chimes strobes speakers other specify. The newest standard requires that fire rated doors be tested for functionality no less than annually and that a written record of the inspection be kept on file for the authority having jurisdiction ahj.
Complete one form for each door inspected.