Armstrong Air Furnace Leaking Water

On january 29 2016 found more water leaking.
Armstrong air furnace leaking water. An air handler that is leaking water on the floor may be the result of a few issues. Check the gas valve at your gas meter the shutoff valve at the furnace and any other shutoff valves. When you see water puddling around the furnace with the a c running you have a clogged condensate drain tube. Improperly designed vent pipe.
Your system might be turned off or your unit might be unplugged. If any are off call the gas company or your local armstrong air dealer to have the gas valves turned back on. Condensation from air conditioning coils contains bacteria that can form slime and clog the condensate pan drain tube. Built with durable materials and incorporating brilliant technology throughout armstrong air is not only the brand to trust with your home comfort it s also the brand more dealers would choose for themselves.
What you have going on. In mild climates like california furnaces and air conditioners are sometimes used during the same season. A malfunction anywhere in this system can cause an air handler to not dispose of water properly and result in water overflowing onto the floor. I had this furnace installed january 2 2014 at cost of 3 455.
Again the most common reason for a leaking furnace is a condensation leak. Is your furnace leaking water when the ac is on. Since 1928 armstrong air has been the smart choice for homeowners who expect more from their heating and cooling system. Leaky humidifier if your furnace has a built in humidifier and the humidifier is clogged or has a leak somewhere in it then that could explain the water pooled.
High efficiency furnaces extract heat from the combustion gases for a longer period of time than a standard efficiency furnace does causing the gases to cool then condense. If the cause of the leaking water is condensation. This makes it seem like you have a furnace leaking water but it s actually the air. Back to top my home is not getting heat potential problems your gas might not be on.
When this happens and your air conditioner is being used the condensation pan fills and water drips onto the heating system. Furnace is leaking when ac is on 1. On april 28 2014 discovered water leaking from furnace. Hose connecting to collector box was leaking.
It s not furnace season so it shouldn t be the furnace that s leaking all the water. Water is produced as a byproduct of the cooling system and typically drains away from the house through a hose or pipe. If your conventional furnace is leaking water it s most likely because of 1 of these 3 reasons. On february 10 2017 we had no heat.
You can prevent slime and eliminate drain tube clogs in two easy steps. Many modern hvac units combine the air conditioner and furnace units for greater efficiency. The condensation is routed to a floor drain.